Resetting the ZDO Procedure
During the update with ZDO, you have a reset option provided that the cutover has not been performed.
Prerequisites
Make sure that phase REQ_ZDO_SYSTEM_BACKUP has not yet been passed.
Context
As long as the users were not rolled over to the bridge subsystem and the phase REQ_USER_ROLLOVER_PREP has not been passed, you can perform a reset during uptime processing as in the standard update procedure.
For more information, see in the SUM Guide the chapter .
However, if the user rollover to the bridge subsystem has already been performed and the phase REQ_USER_ROLLOVER_PREP is completed, the reset works in a two-step approach. If a system backup is performed (see also Backup Strategy for ZDO), the reset function is available until phase REQ_ZDO_SYSTEM_BACKUP.
To reset the procedure, proceed as follows. After finishing both steps, you can start another update using Software Update Manager.